China Standard Low Temperature D Series Cold Room CZPT Unit Cooler wholesaler

Product Description

D Series Cold Area CZPT  Unit Cooler

D-collection Air-cooler is 1 variety of storage CZPT equipment utilised in freon refrigeratiunits, in accordance to applicabie temperature, there are 3 series which includes dl, dd and DJ, which can be used at aifferent storage temperatures. Dl variety air-cooler is largely applicabie to about fresh-preserved storehouses Dd kind air-cooler is mainly applicabie to about -18 chilly storages DJ type CZPT enthusiast is largely applicabie to quick-freezing storages below -25.

This sequence merchandise is geared up with characteristics as follows:
This kind of CZPT fan is specifically designed for preservation, CZPT and chilly storages
1. The shell is created of top quality steel plate Sprayed plastic surface is anti-corrosive, and its look is handsome
two. Coiled pipes are mechanical increasing tubes in staggered arrangement Consequently, copper tubes and aluminum sheets are blended cioseiv, and guarantee very good effect of heat trade. Electrical heating tubes manufactured of great stainless metal are distributed evenly in coiled pipes, and thus ensureexcellent defrosting result. Electrical heating tubes are defriosted by intently conecting Electrical aluminum bushing and holes of fins, as a result, heat is dissipated easily, and thus supporter features long services life.
three. The design and style width of this CZPT enthusiast is reasonabie, place among enthusiast biade and aluminum fin is larger than 1/3 diameter of supporter blade in buy to guarantee ample efficient air volume
four. Lengthy-length air offer ducts can be employed in accordance to customers’requirements
five. For particular-purpose prodcts, please contaes businesses of gaoxiang firm.

Technological Data

Model Refrigerating Capability
W(kcal/h)
Cooling
area (m2)
Pitch of Fins(mm) Unit cooler Electric Defrost
Qty. Dia(mm) Air Stream(m3/h) Pressure Pa(mmH2O) Air Flow(m) Electricity(w) Voltage(v) Coil(kw) Drinking water drain(kw) Voltage(v)
DL-2.1/ten 2100(1800) 11 4.5 one Φ330 2200 98(10) eight 120 380 one. .26 220
DL-3.1/15 3100(2650 fifteen 4.5 two Φ330 two*2200 ninety eight(ten) eight two*120 380 .nine .9 220
DL-4.2/20 4200(3600) twenty four.5 2 Φ330 two*2200 ninety eight(ten) eight 2*a hundred and twenty 380 .nine .9 220
DL-5.2/twenty five 5200(4450) 25 4.5 2 Φ350 2*3000 118(12) ten two*one hundred eighty 380 one.2 1.two 220
DL-8.2/40 8200(7050) 41.5 four.five two Φ400 2*500 147(15) 13 2*250 380 1.five 1.five 220
Dl-11.5/fifty five 11500(9900) fifty five 4.5 2 Φ400 2*five hundred 147(15) thirteen 2*250 380 1.6*2 1.6 380
Dl-16.7/eighty 16700(14360) 80 four.5 two Φ500 two*600 167(seventeen) 13 two*550 380 one.6*2 1.eight 380
Dl-22./105 22000(18900) a hundred and five 4.five 2 Φ500 two*600 167(17) 13 2*550 380 1.8*2 one.8 380
Dl-twenty five.8/125 25800(22200) 127 four.five three Φ500 three*600 167(seventeen) thirteen three*550 380 one.8*2 1.8 380
Dl-33.6/a hundred and sixty 33600(28900) 170 4.5 3 Φ500 3*600 167(seventeen) thirteen 3*550 380 two.4*two two.4 380
Dl-38.7/a hundred and eighty 38700(33300) 186 4.5 four Φ500 four*600 167(17) thirteen four*550 380 three.*two three. 380
Dl-44./210 44000(37850) 214 4.5 4 Φ500 4*600 167(seventeen) 13 four*550 380 3.2*two three. 380
Dl-fifty two.9/260 52900(45500) 264 four.five two Φ600 2*1200 250 16 2*1500 380 one.8*5 one.eight 380
Dl-67.2/330 67200(57800) 335 four.5 3 Φ600 three*1200 250 sixteen 3*1500 380 two.2*5 two.2 380
Dl-eighty one.4/400 83400(71700) 408 4.five 3 Φ600 3*1200 250 16 three*1500 380 two.6*five two.six 380
Product Refrigerating Capacity
W(kcal/h)
Cooling
area (m2)
Pitch of Fins(mm) Unit cooler Electric Defrost
        Qty. Dia(mm) Air Movement(m3/h) Force Pa(mmH2O) Air Movement(m) Electrical power(w) Voltage(v) Coil(kw) Drinking water drain(kw) Voltage(v)
DD-1.4/seven 1400(1200) eight.four six one Φ350 2200 98(ten) eight 120 380 .5*two 0.5 380
DD-2.35/twelve 2350(2000) eleven.5 six 2 Φ350 two*2200 ninety eight(ten) 8 2*120 380 .9*2 0.9 380
DD-3./fifteen 3000(2600) 15.2 six two Φ350 2*2200 ninety eight(ten) 8 2*one hundred twenty 380 .9*2 0.nine 380
DD-4./22 4000(3450) 22.8 six two Φ350 2*3000 118(10) ten 2*a hundred and eighty 380 1.2*two 1.two 380
DD-6./30 6000(5150) 31 6 two Φ400 two*5000 147(15) 10 2*250 380 1.5*2 1.five 380
DD-8./40 8000(6900) 40 six two Φ400 two*5000 147(fifteen) 13 two*250 380 one.8*2 1.8 380
DD-twelve./sixty 12000(10300) sixty 6 2 Φ500 two*6000 167(seventeen) thirteen 2*550 380 one.8*three 1.eight 380
DD-16./80 16000(13750) 81 6 2 Φ500 2*6000 167(seventeen) thirteen 2*550 380 one.6*3 1.8 380
DD-twenty./one hundred 20000(17200) 100 6 3 Φ500 2*6000 167(seventeen) 13 three*550 380 1.6*five 1.eight 380
DD-24./one hundred twenty 24000(20650) 120 six three Φ500 2*6000 167(seventeen) 13 three*550 380 two.4*five 2.four 380
DD-28./140 28000(24100) a hundred and forty 6 4 Φ500 four*6000 167(17) 13 four*550 380 three*5 3. 380
DD-32.1/160 32100(27600) a hundred and sixty six four Φ500 four*6000 167(17) thirteen four*550 380 3.2*5 3.2 380
DD-37.4/200 37400(32200) 200 six 2 Φ600 two*12000 250 16 2*1500 380 two.7*eight 2.seven 380
DD-46.8/250 46800(40300) 250 six 3 Φ600 3*12000 250 16 3*1500 380 three.3*eight 3.3 380
DD-fifty six.2/300 56200(48300) 310 6 three Φ600 three*12000 250 sixteen 3*1500 380 3.5*8 3.5 380
Design Refrigerating Capacity
W(kcal/h)
Cooling
area (m2)
Pitch of Fins(mm) Unit cooler Electric Defrost
        Qty. Dia(mm) Air Flow(m3/h) Stress Pa(mmH2O) Air Movement(m) Energy(w) Voltage(v) Coil(kw) Drinking water drain(kw) Voltage(v)
DJ-13.2/eight 1320(1150) seven.ninety five 9 2 Φ330 two*2200 98(ten) 8 2*one hundred twenty 380 .8*two 0.9 380
DJ-2.3/15 2300(2000) fifteen.9 nine two Φ350 two*3000 118(12) 10 2*a hundred and eighty 380 one.2*two 1.2 380
DJ-4./twenty 4000(2450) twenty nine two Φ400 two*5000 147(15) 13 two*250 380 one.5*two 1.five 380
DJ-5.1/30 5100(4400) thirty nine 2 Φ400 2*5000 147(fifteen) 13 two*250 380 1.6*two 1.6 380
DJ-7.8/forty 7800(6700) 40.two nine two Φ500 two*6000 167(seventeen) 13 2*250 380 1.8*two 1.8 380
DJ-9.8/fifty five 9800(8400) fifty five nine two Φ500 2*6000 167(seventeen) thirteen 2*550 380 one.8*5 1.8 380
DJ-twelve.8/70 12800(11000) 70 9 three Φ500 3*6000 167(17) thirteen three*550 380 one.8*5 1.eight 380
DJ-15.7/eighty five 15700(13500) 85 nine 3 Φ500 three*6000 167(seventeen) thirteen three*550 380 2.4*5 2.four 380
DJ-18.8/100 18800(16160) a hundred 9 4 Φ500 4*6000 167(17) 13 four*550 380 three*five 3. 380
DJ-21.6/115 21600(16600) one hundred twenty 9 2 Φ500 four*6000 167(seventeen) thirteen four*550 380 three.2*five 3.two 380
DJ-23.9/one hundred forty 23900(2 0571 ) 140 nine 2 Φ600 two*12000 250 16 2*1500 380 two.7*8 2.seven 380
DJ-29./170 29000(24900) 178 9 three Φ600 3*12000 250 sixteen three*1500 380 3.3*eight 3.3 380
DJ-35.9/210 35000(30900) 210 9 3 Φ600 three*13000 420 sixteen 3*2200 380 three.5*eight 3.5 380

Application:
one, textile, equipment, ceramics, good chemicals, metallurgy, glass, steel, CZPT and other manufacturing industries
two, electroplating, electronics, footwear, printing, plastics, clothes, printing, packaging, foods processing sector
three, hospitals, waiting around rooms, educational institutions, ready rooms, supermarkets, laundry space
Cooler instance, click to enlarge
1, kitchen, vegetable market place, a big enjoyment center, underground parking, railway stations and other general public places greenhouse, bouquets, poultry, CZPT and other types of farms
two, the current air conditioning and blower gear modification and installation.
three, the specifications of higher humidity locations (this kind of as textiles, planting, etc.), can be part of the interior set up layout.
four, the requirements of minimal humidity, low humidity and substantial cleanliness of the location, make sure you cautiously think about the suitability of use.

 

Two varieties of AC motors include: Synchronous: The truth that a synchronous motor rotates at the very same charge as the frequency of the mains present presents the motor its identify. A synchronous motor is made up of a stator and a rotor. Synchronous motors have a vast selection of applications. Induction: Induction motors are the simplest and strongest motors obtainable. These AC motors consist of two electrical factors: a wound stator and rotor assembly. The recent necessary to flip the rotor is created by the electromagnetic induction produced by the stator windings. Induction motors are a single of the most generally utilised types of motors in the world.
An AC motor is a widespread sort of electric powered motor that is driven by alternating existing. As the most successful practical motors for daily industrial programs (as properly as hobbyist tasks, family items, and all other expert tools and buyer merchandise), AC motors provide a fairly efficient approach of generating mechanical vitality from a simple electrical input signal.

China Standard Low Temperature D Series Cold Room CZPT Unit Cooler     wholesaler

Tags: